Water Heaters

Elwa Hotrun

Our Hotruns are compact in size 315 x 204 x 130mm (approximate size A4 paper) , they are energy efficient and never run out of hot water.

It’s important to choose the right capacity hot water system to meet your needs both now and in the future. When considering your options think about your hot water usage patterns like the number of people using hot water from different outlets at the same time, and whether you are likely to use more hot water at certain times of the day. The flow of hot water delivered by instantaneous water heaters depends on the condition where the water heater is installed, and the rated power (capacity).

The cold water inlet temperature in all seasons (climate-zone) determines how hard the water heater needs to work to deliver the flow of water required at the right temperature. That is why we prefer to give you personalised advice what model ELWA Hotrun is best for your application at your location.

Elwa NANO and HOTRUN 2016 chart of new range

 

HOTRUN 38VE

A HOTRUN 38VE is generally used for single point of use hand wash basin, not suitable for kitchens / showers / baths. This model has a variable digital programmable temperature limiter to 38, 45 or 50°C depending on the situation, for example HOTRUN 38VET-50, ELWA product code 21380 for a model with a 50°C limiter built-in.
Water connections: Each HOTRUN 38 comes with a fitted electric cord and 2 flexible hoses and a 1.9 ltr/min flow regulator easy to connect always with supplied 1/2″ BSP flexible hoses. The flow regulator is fitted on or in the cold water inlet fitting of the water heater. Normal mains pressure is required (min 60 kPa constant)
Electrical connection: A HOTRUN 38VE needs a dedicated single phase 16Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned next to the HOTRUN on the right hand side.
(Download  Elwa Hotrun 38VE data sheet) (Download Product Brochure ELWA NANO & VE A4-2016)

 

 

 

HOTRUN 48VE

A HOTRUN 48VE is generally used for single point of use hand wash basin applications in cooler climates instead of a  HOTRUN 38VE, in warmer climates for small kitchenettes etc. not suitable for kitchens/showers/baths.
This model has a variable digital programmable temperature limiter to 38, 45 or 50°C depending on the situation, for example HOTRUN 48VET-45, ELWA product code 2114845 for a model with a 45°C limiter built-in.
Water connections: Each HOTRUN 48VE comes with a fitted electric cord and 2 flexible hoses and a 2.5 ltr/min flow regulator easy to connect always with supplied 1/2″ BSP flexible hoses. The flow regulator is fitted on or in the cold water inlet fitting of the water heater. Normal mains pressure is required (min 60 kPa constant)
Electrical connection: A HOTRUN 48VE needs a dedicated single phase 20Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned right next to the HOTRUN on the right hand side.
(Download Elwa Hotrun 48VE data sheet)  (Download Product Brochure ELWA NANO & VE A4-2016)

 

 

HOTRUN 60VE

A HOTRUN 60VE is generally used for single or double hand wash applications and for small kitchenettes etc. not suitable for residential or commercial kitchen sinks/showers/baths. Unless used for a kitchenette this model has a variable digital programmable temperature limiter to 38, 45 or 50°C depending on the situation, for example HOTRUN 60VET-50 ELWA product code 216050 for a model with a 50°C limiter built-in.
Water connection: Each HOTRUN 60VE comes with a fitted electric cord and 2 flexible hoses and a specific flow regulator of 3 ltr/min, ready to connect always with supplied 1/2″ BSP flexible hoses. The supplied flow regulator is fitted on or in the cold water inlet fitting of the water heater. Normal mains pressure is required (min 60 kPa constant)
Electrical connection: A HOTRUN 60VE needs a dedicated single phase 25Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned next to the HOTRUN on the right hand side.
(Download Elwa Hotrun 60VE data sheet)  (Download Product Brochure ELWA NANO & VE A4-2016)

 

 

HOTRUN 75VE

A HOTRUN 75VE is suitable for single or double hand wash applications and in warmer climate areas for a kitchen sink and shower etc. Not suitable to fill a bath. Unless used for a kitchen this model has a variable digital programmable temperature limiter to 38, 45 or 50°C depending on the situation, for example HOTRUN 75VET-50, ELWA product code 227550 for a model with a 50°C limiter built-in
Water connections: Each HOTRUN 75VE comes with a fitted electric cord and 2 flexible hoses and a flow regulator of 4 ltr/min, ready to connect always with supplied 1/2″ BSP flexible hoses. The supplied flow regulator is fitted on or in the cold water inlet fitting of the water heater. Normal mains pressure is required (min 60 kPa constant)
Electrical connection: A HOTRUN 75VE needs a dedicated single phase 32Amp or double pole 16Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned next to the HOTRUN on the right hand side.
(Download Elwa Hotrun 75VE data sheet)  (Download Product Brochure ELWA NANO & VE A4-2016)

 

 

HOTRUN 96VE

A HOTRUN 96VE is suitable for double hand wash applications, kitchen sink and shower etc. Unless used for a kitchenette this model has a variable digital programmable temperature limiter to 38, 45 or 50°C depending on the situation, for example HOTRUN 96T-50, ELWA product code 229050 for a model with a 50°C limiter built-in.
Water connections: Each HOTRUN 96VE comes with a fitted electric cord and 2 flexible hoses and a flow regulator of 5ltr/min, ready to connect always with supplied 1/2″ BSP flexible hoses. The supplied flow regulator is fitted on or in the cold water inlet fitting of the water heater. Normal mains pressure is required (min 60 kPa constant)
Electrical connection: A HOTRUN 96 needs a dedicated single phase 40Amp or double pole 20Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned next to the HOTRUN on the right hand side.
(Download Elwa Hotrun 96VE data sheet)  (Download Product Brochure ELWA NANO & VE A4-2016)

 

 

HOTRUN 120VE

Elwa Hotrun 120VE front view white background, no cables

Hotrun size 255x190x95mm


A HOTRUN 120VE is suitable for multiple hand wash applications, kitchen sink, one shower, apartments etc. This model has a programmable temperature limiter that can be preset to any temperature, and the user can set a preferred temperature lower than the preset limit on the digital controller
Water connections: Each HOTRUN 120VE can have the water connections from the bottom of the unit with 2 flexible hoses supplied (or from the back). Normal mains pressure is required (min 60 kPa constant) and needs to be limited to max 600kPA
Electrical connection: A HOTRUN 120 needs a dedicated 3-phase 16Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned on the right hand side; fitted cord can be changed to the left.
(Download Product Brochure ELWA NANO & VE A4-2016)

HOTRUN 150VE

A HOTRUN 150VE is suitable for multiple hand wash applications, kitchen sink, one shower, apartments etc. This model has a programmable temperature limiter that can be preset to any temperature, and the user can set a preferred temperature lower than the preset limit on the digital controller
Water connections: Each HOTRUN 150VE can have the water connections from bottom of the unit with 2 flexible hoses supplied (or from the back). Normal mains pressure is required (min 60 kPa constant) and needs to be limited to max 600kPA
Electrical connection: A HOTRUN 150 needs a dedicated 3-phase 20Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned on the right hand side; fitted cord can be changed to the left.
(Download Product Brochure ELWA NANO & VE A4-2016)

HOTRUN 180VE

A HOTRUN 180VE is suitable for multiple hand wash applications, kitchen sink, one or two showers, residential applications etc. This model has a programmable temperature limiter that can be preset to any temperature, and the user can set a preferred temperature lower than the preset limit on the digital controller
Water connections: Each HOTRUN 180VE can have the water connections from the bottom of the unit with 2 flexible hoses supplied (or from the back). Normal mains pressure is required (min 60 kPa constant) and needs to be limited to max 600kPA
Electrical connection: A HOTRUN 180 needs a dedicated 3-phase 25Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned next to the HOTRUN on the right hand side; fitted cord can be changed to the left.
(Download Product Brochure ELWA NANO & VE A4-2016)

HOTRUN 210VE

A HOTRUN 210VE is suitable for multiple hand wash applications, kitchen sink, one or two showers, residential applications etc. This model has a programmable temperature limiter that can be preset to any temperature, and the user can set a preferred temperature lower than the preset limit on the digital controller
Water connections: Each HOTRUN 210VE can have the water connections from the bottom of the unit with 2 flexible hoses supplied (or from the back). Normal mains pressure is required (min 60 kPa constant) and needs to be limited to max 600kPA
Electrical connection: A HOTRUN 210 needs a dedicated 3-phase 32Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned on the right hand side; fitted cord can be changed to the left.
(Download Product Brochure ELWA NANO & VE A4-2016)

HOTRUN 240VE

A HOTRUN 240VE is suitable for multiple hand wash applications, kitchen sink, one or two showers, residential applications etc. This model has a programmable temperature limiter that can be preset to any temperature, and the user can set a preferred temperature lower than the preset limit on the digital controller.
Water connections: Each HOTRUN 240VE can have the water connections from the bottom of the unit with 2 flexible hoses supplied (or from the back). Normal mains pressure is required (min 60 kPa constant) and needs to be limited to max 600kPA
Electrical connection: A HOTRUN 240 needs a dedicated 3-phase 40Amp circuit direct from the distribution board hard wired usually to an isolator switch positioned on the right hand side; fitted cord can be changed to the left.  (Download Product Brochure ELWA NANO & VE A4-2016)